This topic is a quick reference when creating views to register within the framework amd speaks to simple examples. Each view type can have greater complexity and may have alternative configurations.
Include the key in views, as a general rule. If a key is not included, add a control to a column in Syniti Construct and mark it as a key.
Include boaStatus on the table for it to appear in Syniti Construct. It is not required to include boaStatus in the view as well.
Create columns for button/images/tabs/labels/toolbar controls, or any other columns that should not be updated, by aliasing a column on a view. These columns cannot be edited in Syniti Construct.
Order the columns on a page by setting the column order in the view. The column order on a view dictates the column order on a page.
Match prefixes and suffixes with the naming conventions set for the targeted WebApp.
Include the underlying page table and be descriptive when naming views.
Use the strict naming feature when possible.
Make views as simple as possible. It’s better to create several simple views and join them into a separate view.
Horizontal View
Default Naming Convention: web*Hor
Registered on the Pages page
Most common default view for Dynamic pages
View required for Header Detail pages, both parent and child
Vertical View
Default Naming Convention: web*Ver
Registered on the Pages page
Displays on selection of Vertical icon on Horizontal pages and on Vertical Only pages
If a page has a Horizontal and Vertical View, they typically reference the same table or view as source (but the views can reference other sources as needed)
Can be used to show key-bound detail data for the Horizontal view. In this case, select a table or view that shares the primary key. For example, Order can be the Horizontal, Order Details can be the Vertical, binding on OrderID.
Toolbar View
Default Naming Convention: web*Tbv
Registered on the Pages page
Used to create custom buttons at the page toolbar level in 6.1 and later; can also be applied to the site toolbar in 6.0 and previous
Do not need to select a table or view
View may only return one row when executed for the page
Each Alias on the view will be available for selection as a toolbar control on the Page Columns page
Can contain multiple values
Use a unique name (different than Horizontal and Vertical columns). Using non-unique names is allowed, but may result in confusion when assigning controls and when designing the page.
Use NULL with an alias on the Horizontal or Vertical to create row buttons or row images
Use plain text, as the control allows for configuration of an image and page link.
Refer to Add a Toolbar Button for more information.
List View
Default Naming Convention: web*List
Registered on the Page Columns page Vertical view when Control is a List or Combo Box
Used as the list source for list box and combo box
Select columns that are available on list boxes and combo boxes
Select a table or view that contains the desired columns and values
When configuring a column, the Key is the List Value and the Descriptor for the Key is the List Display
Do not use the underlying page table for the source
Refer to Add List Boxes and Combo Boxes for more information.
Validation View
Default Naming Convention: web*Val
Registered on the Page Validation Rules page Vertical view when Validation Type is View
Used to run data validation rules against page data for any Event type, both page and row level, though most validations are row level and require a key
Validations can be run as a page event and do not require a key, but the event is run against the whole table or view. It is important to understand your page views in this scenario.
Select only the columns required to run the rule, or the columns helpful to the user on the notifications
If a key is not selected, the rule is applied at the page level and run against all records
Refer to Validation Rules for more information.
Default View
Default Naming Convention: web*Def
Registered on the Page Columns page Vertical view
Sets default value for column in insert mode
Do not select the base table or view; the default view must return one row when executed in add mode
Column is the default value to be used
Alias is column name affected; name must be exact
Note, this is different from the below default methods:
CranSoft column property default
Set default on table
Refer to Defaults Views for more information.
Hover View
Default Naming Convention: web*Hov
Registered on the Pages page or Page Columns page Vertical view for List and Combo Boxes
Returns the column values from a view for the selected row on the data grid
When assigned to a page, the hover text appears when hovering the cursor over the page title
When assigned to a column, the hover text appears when hovering the cursor over the column value
Refer to Hover Views fore more information.
Data Control View
Default Naming Convention: web*Dcv
Registered on the Pages page
Controls how data is presented on a row on a page based on data in the row
Include the table key, as the view must return only zero or one row per row in the data grid.
Select columns from table
0=Disable, 1=Enable, 2=Hide
Refer to Data Control Views for more information.
User Control View
Default Naming Convention: web*Ucv
Registered on the Pages page
Controls column availability based on the session UserEmail
0=Disable, 1=Enable, 2=Hide
Alias the desired state (0, 1, 2) as boaControlStatus
Alias the affected column names as boaColumn
Also works well for disabling boa reserved columns, such as:
boaAudit
boaInsert
boaUpdate
boaDelete
Filters on the current user listed in the boaUserEmail column
Refer to User Control Views for more information.
Page Control View
Default Naming Convention: web*Pcv
Registered on the Pages page
Controls column availability based on data from a parent page
Select columns from child table (registered to child page during configuration)
This control view must be on the child page, and is only effective if drilled from parent to child page. Example would be from Orders > OrderDetails.
0=Disable, 1=Enable, 2=Hide
Refer to Page Control View for more information.
Parameter View
Default Naming Convention: web*PV
Registered on the Page Business Rules page Vertical view when Procedure Type is WebApp Event
Provides the parameters needed for WebApp Events and External Events
This is the page that is calling the public event
Select columns from a table
Selected columns can be selected as event parameters
Required when the event runs at the row level
Refer to Set Parameters for a Public WebApp Event for more information.
Watermark View
Default naming convention: web*Dwv
Registered on the Page Columns page
Provides the text displayed in the column registered
Limited to 30 characters
No need to select table or view
Alias desired text as 'boaWatermark '
Refer to Add a Watermark for more information.
Tooltip View
Default naming convention: web*Dtv
Provides the tooltip text displayed in the column registered
Limited to 30 characters
No need to select table or view
Alias desired text as 'boaTooltip'